*** PFR ENGINEERING SYSTEMS        **                                  **  JOB  NR :   002  ** MOD :  5.7    PAGE:  4
*** PROGRAM : FURCRAK-1            **     FINAL PRINTOUT(GAS SIDE)     **  REF  NR :        ** ENG : A.CALIN         
*** SERVICE :       TEST           **                                  **  PROP NR :        ** USER:                 
---------------------------------------------------------------------------------------------------------------------

                                   ***** OVERALL TUBE SIDE INFORMATION *****
 
                                   TOTAL HEAT ABSORBED IN THE FIREBOX(BTU/HR)       =0.77208E+08
                                   TOTAL HEAT ABSORBED IN EACH COIL(BTU/HR)         =0.19302E+08
                                   AVERAGE OUTSIDE HEAT FLUX(BTU/HR/FT2)            = 18644.    
                                   EFFICIENCY BASED ON LHV(FRCT)                    =0.39958    
                                   EFFICIENCY BASED ON TOTAL HEAT INPUT(FRCT)       =0.39880    
                                   OUTSIDE SURFACE OF EACH COIL(FT2)                = 1035.3    
                                   TOTAL OUTSIDE SURFACE OF COILS(FT2)              = 4141.1    

                                   ***** OVERALL FEED INFORMATION *****
                                   INPUT FEED TEMP(DEG F)                           = 1196.0    
                                   INPUT FEED ENTHALPY(BTU/LB)                      =0.20000E-02
                                   OUTPUT FEED TEMPERATURE(DEG F)                   = 1565.8    
                                   OUTPUT FEED ENTHALPY(BTU/LB)                     = 1037.2    
                                   FLOW OF FEED PER ROW IN EACH COIL(LB/HR)         = 9305.0    
                                   TOTAL FLOW OF FEED(LB/HR)                        = 74440.    

--------------------------------------------------------------------------------------------------------------------
*** PFR ENGINEERING SYSTEMS       **                                  **  JOB  NR :   002  ** MOD :  5.7    PAGE:  5
*** PROGRAM : FURCRAK-1           **     FINAL PRINTOUT(GAS SIDE)     **  REF  NR :        ** ENG : A.CALIN         
*** SERVICE :       TEST          **                                  **  PROP NR :        ** USER:                 
---------------------------------------------------------------------------------------------------------------------

                                   ***** OVERALL GAS SIDE INFORMATION *****
                                                       (SEE NOTE 2)
                                     --------------------------------------------------------
                                     GAS ZONE    POSITION    POSITION    POSITION     TEMP OF
                                       NUMBER       ALONG       ALONG       ALONG    GAS ZONE
                                                   HEIGHT  HALF WIDTH      LENGTH     (DEG F)
                                               OF FIREBOX  OF FIREBOX  OF FIREBOX
                                     --------------------------------------------------------
                                            1           1           1           1     2256.6    
                                            2           1           1           2     2516.5    
                                            3           1           1           3     2335.4    
                                            4           1           1           4     2347.7    
                                            5           1           1           5     2527.5    
                                            6           2           1           1     2253.8    
                                            7           2           1           2     2518.3    
                                            8           2           1           3     2336.3    
                                            9           2           1           4     2350.2    
                                           10           2           1           5     2536.0    
                                           11           3           1           1     2236.7    
                                           12           3           1           2     2390.3    
                                           13           3           1           3     2457.9    
                                           14           3           1           4     2206.6    
                                           15           3           1           5     2530.3    
                                           16           4           1           1     2223.3    
                                           17           4           1           2     2333.5    
                                           18           4           1           3     2372.4    
                                           19           4           1           4     2135.3    
                                           20           4           1           5     2523.0    
                                           21           5           1           1     2054.4    
                                           22           5           1           2     2148.7    
                                           23           5           1           3     2179.5    
                                           24           5           1           4     2040.3    
                                           25           5           1           5     2303.7    
                                   AVERAGE WEIGHTED GAS ZONE TEMP(DEG F)            =   2317.9    
                                   EXIT FLUE GASES MIXED TEMP(DEG F)                =   2128.0    
                                   EXIT FLUE GASES MIXED ENTHALPY(BTU/LB)           =   627.66    
                                   HEAT FLOW IN EXIT FLUE GASES(BTU/HR)             =  0.11557E+09
                                   HEAT LOSSES THROUGH REFRACTORY WALLS(BTU/HR)
                                        FRONT WALL                  = 41934.    
                                        RIGHT WALL                  =0.38128E+06
                                        BACK WALL                   =0.00000    
                                        LEFT WALL                   =0.38128E+06
                                        FLOOR WALL                  = 45698.    
                                        ROOF WALL                   = 41588.    
                                   TOTAL HEAT LOST THROUGH REFRACTORY               =  0.89178E+06
                                   EFFICIENCY BY FLUE GAS BALANCE-LHV BASIS-(FRCT)  =  0.39920    
                                   EFFICIENCY BY FLUE GAS BALANCE-  TOTAL  -(FRCT)  =  0.39843    
                                                              HEAT INPUT BASIS