Following is an excerpt from an FRNC-5PC output

 

  ** PFR DIRECT FIRED HEATER COMPUTER PROGRAM **                   ** FURNACE ID -                         ** FRNC-5 **  MOD 6.6
  ** FINAL PRINTOUT **                                             ** LOCATION -HERE IS                    ** U.S.  UNITS     **
  ** SERVICE-REFORMER REACTOR FURNACE                              ** ENGINEER -JIM F.                     ** CASE ID-TEST 5  **
  -- REV 0000.PC660  05/01/2000 ------------------------------------------------------------------------------------------------
   ** FRNC5 TEST CASE 5 - REFORMER REACTOR FURNACE                
   **                                                             
   **                                                             

   *FURNACE ID.-             LOCATION - HERE IS         SERVICE - REFORMER REACTOR FURNACE          CASE ID.- TEST 5  
   -------------------------------------------------------------------------------------------------------------------

   *TOTAL DUTY, MMBTU/HR     176.614   FIRING RATE, MMBTU/HR     222.800  PERCENT DUTY ABSORBED IN FIREBOX(ES)    61.6
    NO.OF NON-IDENTICAL FIREBOXES  4   EFFICIENCY (LHV), PCT.     79.0    FLUE GAS STACK ENTRY TEMPERATURE (F)   714.0
                                       EFFICIENCY (HHV), PCT.     72.5
                                      (TOTAL HEAT INPUT BASIS)


    FIREBOX ID.- 10  NO.FIREBOXES  1   FIRING RATE,MMBTU/HR   100.100   EXCESS AIR,PCT  37.7   GAS TEMP.LEAVING (F) 1688.1
                                            (LHV BASED)                                          (BRIDGEWALL)
    FIREBOX ID.- 20  NO.FIREBOXES  1   FIRING RATE,MMBTU/HR    49.500   EXCESS AIR,PCT  37.7   GAS TEMP.LEAVING (F) 1701.7
                                            (LHV BASED)                                          (BRIDGEWALL)
    FIREBOX ID.- 30  NO.FIREBOXES  1   FIRING RATE,MMBTU/HR    41.450   EXCESS AIR,PCT  37.7   GAS TEMP.LEAVING (F) 1439.6
                                            (LHV BASED)                                          (BRIDGEWALL)
    FIREBOX ID.- 40  NO.FIREBOXES  1   FIRING RATE,MMBTU/HR    31.750   EXCESS AIR,PCT  37.7   GAS TEMP.LEAVING (F) 1550.0
                                            (LHV BASED)                                          (BRIDGEWALL)





   *PROCESS STREAM INFORMATION   ( * FLAGS USER INPUT)

    PROCESS ABSORBED  FLOW      TEMPERATURE (F) PRESSURE(PSIA)  PRESSURE WT.FRACT.VAPOR ENTHALPY BTU/LB 
    STREAM  DUTY,     RATE,     --------------- ---------------   DROP   -------------- --------------- 
    ID.     MMBTU/HR  MLB/HR    INLET    EXIT   INLET    EXIT    (PSI)   INLET    EXIT  INLET    EXIT   
    ------- --------  --------  ------  ------  ------  ------  -------- -----   -----  ------  ------  
    10         46.54    308.40*  773.0*  947.0   357.7*  355.4     2.32  1.000   1.000   621.8*  772.7 
    20         56.69    308.40*  739.7*  953.5   345.7*  324.5    21.17  1.000   1.000   597.3*  778.5 
    30         23.08    308.40*  893.0*  976.9   326.7*  322.7     3.97  1.000   1.000   724.7*  799.5 
    40         16.33    308.40*  920.0*  979.0   306.7*  292.2    14.54  1.000   1.000   748.6*  801.6 
    60         33.98    177.70*  497.0*  499.0   694.2*  674.8    19.36   .000    .264   484.4*  675.6 

 

  ** PFR DIRECT FIRED HEATER COMPUTER PROGRAM **                   ** FURNACE ID -                         ** FRNC-5 **  MOD 6.6
  ** FINAL PRINTOUT **                                             ** LOCATION -HERE IS                    ** U.S.  UNITS     **
  ** SERVICE-REFORMER REACTOR FURNACE                              ** ENGINEER -JIM F.                     ** CASE ID-TEST 5  **
  -- REV 0000.PC660  05/01/2000 ------------------------------------------------------------------------------------------------
   ** FRNC5 TEST CASE 5 - REFORMER REACTOR FURNACE                
   **                                                             
   **                                                             

  **FLUE GAS SIDE INFORMATION** 
    -------------------------  

   *FOLLOWING FURNACE SECTIONS ARRANGED IN ORDER OF GAS CONTACT*

 ***********************************************************************************************************************

     FURNACE SECTION  FLUE  GAS    GAS FLOW RATE   GAS TEMP.(F)  PRESSURE,IN.H2O GAGE    HEAT       HEAT     VOL. HEAT
    ----------------- ---------  ----------------- ------------- --------------------  ABSORBED     LOST      RELEASE 
     ID.     TYPE     ID.  SEQ.    MLB/HR   MSCFM  INLET   EXIT   INLET         ROOF  (MMBTU/HR) (MMBTU/HR) BTU/HR/FT3 
    ---- ------------ ---- ----  -------- -------- ------ ------ -------      ------- ---------- ---------- ----------
     10    FIREBOX    1050   1      113.6    25.46 1838.6 1688.1   -.683        -.199     46.545      1.001      9176.

 ***********************************************************************************************************************

     FURNACE SECTION  FLUE  GAS    GAS FLOW RATE   GAS TEMP.(F)  PRESSURE,IN.H2O GAGE    HEAT       HEAT     VOL. HEAT
    ----------------- ---------  ----------------- ------------- --------------------  ABSORBED     LOST      RELEASE 
     ID.     TYPE     ID.  SEQ.    MLB/HR   MSCFM  INLET   EXIT   INLET         ROOF  (MMBTU/HR) (MMBTU/HR) BTU/HR/FT3 
    ---- ------------ ---- ----  -------- -------- ------ ------ -------      ------- ---------- ---------- ----------
     20    FIREBOX    1051   2       56.2    12.59 1854.7 1701.7   -.683        -.199     22.843       .495      9864.

 ***********************************************************************************************************************

     FURNACE SECTION  FLUE  GAS    GAS FLOW RATE   GAS TEMP.(F)  PRESSURE,IN.H2O GAGE    HEAT       HEAT     VOL. HEAT
    ----------------- ---------  ----------------- ------------- --------------------  ABSORBED     LOST      RELEASE 
     ID.     TYPE     ID.  SEQ.    MLB/HR   MSCFM  INLET   EXIT   INLET         ROOF  (MMBTU/HR) (MMBTU/HR) BTU/HR/FT3 
    ---- ------------ ---- ----  -------- -------- ------ ------ -------      ------- ---------- ---------- ----------
     30    FIREBOX    1052   3       47.1    10.54 1590.0 1439.6   -.683        -.199     23.079       .414      4750.

 ***********************************************************************************************************************

     FURNACE SECTION  FLUE  GAS    GAS FLOW RATE   GAS TEMP.(F)  PRESSURE,IN.H2O GAGE    HEAT       HEAT     VOL. HEAT
    ----------------- ---------  ----------------- ------------- --------------------  ABSORBED     LOST      RELEASE 
     ID.     TYPE     ID.  SEQ.    MLB/HR   MSCFM  INLET   EXIT   INLET         ROOF  (MMBTU/HR) (MMBTU/HR) BTU/HR/FT3 
    ---- ------------ ---- ----  -------- -------- ------ ------ -------      ------- ---------- ---------- ----------
     40    FIREBOX    1053   4       36.0     8.07 1703.1 1550.0   -.683        -.199     16.325       .317      6327.

 ***********************************************************************************************************************

     FURNACE SECTION  FLUE  GAS    GAS FLOW RATE     MASS    GAS TEMP.(F)  PRESSURE,IN.H2O GAGE    HEAT       HEAT   
    ----------------- ---------  ----------------- VELOCITY  ------------- --------------------  ABSORBED     LOST   
     ID.     TYPE     ID.  SEQ.    MLB/HR   MSCFM  LB/HR/FT2 INLET   EXIT   INLET         DROP  (MMBTU/HR) (MMBTU/HR)
    ---- ------------ ---- ----  -------- -------- --------- ------ ------ -------      ------- ---------- ----------
     50    CONVECT.   1054   5      252.9    56.66    571.19 1625.7 1180.6   -.199         .015     33.843       .316

 ***********************************************************************************************************************

     FURNACE SECTION  FLUE  GAS    GAS FLOW RATE     MASS    GAS TEMP.(F)  PRESSURE,IN.H2O GAGE    HEAT       HEAT   
    ----------------- ---------  ----------------- VELOCITY  ------------- --------------------  ABSORBED     LOST   
     ID.     TYPE     ID.  SEQ.    MLB/HR   MSCFM  LB/HR/FT2 INLET   EXIT   INLET         DROP  (MMBTU/HR) (MMBTU/HR)
    ---- ------------ ---- ----  -------- -------- --------- ------ ------ -------      ------- ---------- ----------
     60    CONVECT.   1054   6      252.9    56.66    743.45 1180.6  714.0   -.214         .101     33.979       .110

 ***********************************************************************************************************************

     FURNACE SECTION  FLUE  GAS    GAS FLOW RATE     MASS    GAS TEMP.(F)   INLET     DRAFT LOSSES,  IN.H2O GAGE   HEAT   
    ----------------- ---------  ----------------- VELOCITY  ------------- PRESSURE  ---------------------------    LOST   
     ID.     TYPE     ID.  SEQ.    MLB/HR   MSCFM  LB/HR/FT2 INLET   EXIT  IN.H2O G  DAMPER ENTR.   EXIT  FRICT. (MMBTU/HR)
    ---- ------------ ---- ----  -------- -------- --------- ------ ------ --------  ------ ------ ------ ------ ----------
     70    STACK      1054   7      252.9    56.66   4050.36  714.0  696.0    -.314    .171   .056   .110   .019      1.249

 

  ** PFR DIRECT FIRED HEATER COMPUTER PROGRAM **                   ** FURNACE ID -                         ** FRNC-5 **  MOD 6.6
  ** FINAL PRINTOUT **                                             ** LOCATION -HERE IS                    ** U.S.  UNITS     **
  ** SERVICE-REFORMER REACTOR FURNACE                              ** ENGINEER -JIM F.                     ** CASE ID-TEST 5  **
  -- REV 0000.PC660  05/01/2000 ------------------------------------------------------------------------------------------------
   ** FRNC5 TEST CASE 5 - REFORMER REACTOR FURNACE                
   **                                                             
   **                                                             

   **TUBESIDE INFORMATION**
     --------------------

   **PROCESS STREAM    ID.- 10        REFORMER GAS                            
                                                                              


     COIL  COIL    FURN.   HEAT    PRESS.DROP(PSI) FLUE GAS TEMP  FLUE GAS PRESS.   FLUE GAS
     SECT SECTION  SECT.   DUTY    --------------- ---- (F) ----    IN.H2O GAGE  MAXIMUM VEL.
      ID.  TYPE      ID. (MM-B/HR) TOTAL   HEADERS  INLET   EXIT   INLET    DROP (LB/SEC/FT2)
     ---- -------  ----- --------- ------  ------- ------ ------  ------- ------- -----------
      10  RADIANT    10     19.320    1.2       .5 1688.1 1688.1     .000    .000      .00000
      11  RADIANT    10      8.937     .4       .2 1688.1 1688.1     .000    .000      .00000
      12  RADIANT    10     18.288     .7       .3 1688.1 1688.1     .000    .000      .00000


     TERMINAL CONDITIONS OF EACH COIL SECTIONS***

     COIL POINT PROC. PRESS- TEMPER- ENTHALPY WEIGHT VELOCITY CRITICAL    MASS     HOMOGEN.  FLOW    BOILING 
     SECT INFO. FLOW  URE    ATURE            FRACT.          VELOCITY  VELOCITY   REYNOLDS                  
      ID.  AT   SEQ.  (PSIA)  (F)     (B/LB)  VAPOR   (FT/S)   (FT/S) (LB/SEC/FT2) NUMBER    REGIME  REGIME  
     ---- ----- ----- ------ ------- -------- ------ -------- -------- ----------- -------- -------- --------
      10  INLET   1    357.7   773.0   621.81  1.000     44.9   1437.7      38.909  784543. TURBULNT SENSIBLE
      10  EXIT    1    356.5   846.9   684.45  1.000     47.8   1479.6      38.909  767112. TURBULNT SENSIBLE
      11  EXIT    2    356.1   880.1   713.43  1.000     49.1   1497.9      38.909  747783. TURBULNT SENSIBLE
      12  EXIT    3    355.4   947.0   772.73  1.000     51.6   1534.1      38.909  723165. TURBULNT SENSIBLE

     COIL POINT *CONVECTIVE HEAT TRANSFER COEFFICIENT *  *FOULING RESISTANCE* *HEAT FLUX BASED ON BARE TUBE AREA(BTU/HR/FT2)*
     SECT INFO. *            (BTU/HR/FT2/F)           *  * 1/(BTU/HR/FT2/F) * *  RADIANT    * *  CONVECTIVE * *    TOTAL    *
      ID.  AT   INSIDE      OUTSIDE    HO+FIN   OVERALL  INSIDE       OUTSIDE AVERAGE    PEAK AVERAGE    PEAK AVERAGE    PEAK
     ---- ----- --------- --------- --------- ---------  ---------  --------- ------- ------- ------- ------- ------- ------- 
      10  INLET    288.42      2.00      2.00      1.97      .0010      .0000 10052.5 19749.6  1924.3  3078.9 11976.8 22828.5
      10  EXIT     290.73      2.00      2.00      1.97      .0010      .0000  9910.3 19470.2  1853.9  2966.2 11764.2 22436.5
      11  EXIT     295.90      5.00      5.00      4.83      .0010      .0000  9651.9 18962.4  4345.5  6952.8 13997.4 25915.3
      12  EXIT     301.33      2.00      2.00      1.97      .0010      .0000  9463.6 18592.5  1662.0  2659.2 11125.6 21251.7

 COIL POINT **********  T   E   M   P   E   R   A   T   U   R   E   S     (  F  )  **********
 SECT INFO. *INSIDE FILM* *INSIDE  WALL* *AVERAGE WALL* *OUTSIDE WALL* *OUTSIDE FILM* FIN TIP
  ID.  AT    AVER.  PEAK    AVER.  PEAK    AVER.  PEAK    AVER.  PEAK    AVER.  PEAK    PEAK
 ---- ----- ------ ------ ------- ------ ------- ------ ----(SKIN)---- ------- ------ -------
  10  INLET  823.1  866.2   837.6  893.1   847.7  911.9   857.8  930.7   857.8  930.7      .0
  10  EXIT   895.8  937.8   910.0  964.3   919.9  982.7   929.8 1001.2   929.8 1001.2      .0
  11  EXIT   937.2  983.7   954.1 1014.4   965.9 1035.8   977.7 1057.2   977.7 1057.2      .0
  12  EXIT   991.6 1030.2  1005.0 1055.2  1014.4 1072.7  1023.8 1090.3  1023.8 1090.3      .0